Asset Twin example

NDE - Comp B

Low Not assessed  Compressor on Cooling / CL-COMP-B

Not in alert.

Likely faults

FaultLikelihoodSeen on
VFD electrical noise 60% stream 441e54f2
Soft foot 30% stream 441e54f2
Loose connections 10% stream 441e54f2

Each axis is analysed on its own; a fault seen on several shows the highest likelihood any of them reports, never a sum.

What changed

No active changes.

Trends

Measurement time 2026-09-27 11:04 to 2026-10-27 13:43 (UTC). ▏went into alert · ▏back to low, cleared or as the evidence faded — from Multiviz's priority history.

Vibration level

How strongly the machine vibrates at this point. A rise here is what usually lies behind an alert: compare it with the alert marks.

Velocity RMS · mm/s Stream 441e54f2 0 mm/s Stream cdd367d6 0 mm/s Stream ef24e7c0 0 mm/s
0 1 2 3 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 18 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Impacting

Short, sharp impacts, as from a damaged bearing, raise crest factor and kurtosis — often before the overall level moves.

Acceleration RMS · g Stream 441e54f2 0 g Stream cdd367d6 0 g Stream ef24e7c0 0 g
0.0 0.2 0.4 0.6 0.8 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 18 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Crest factor · peak ÷ RMS, no unit Stream 441e54f2 0 Stream cdd367d6 0 Stream ef24e7c0 0
0 2 4 6 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 18 h.

Kurtosis · no unit; about 3 when nothing is impacting Stream 441e54f2 0 Stream cdd367d6 0 Stream ef24e7c0 0
0 1 2 3 4 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 18 h.

Operating conditions

What the machine was doing. A change in speed or temperature explains many changes in vibration.

Temperature · °C latest 0 °C
0 10 20 30 40 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Speed

Nothing recorded for this measuring point yet.

Sensor health

About the sensor, not the machine: a flat battery or a weak signal shows up as gaps in the data.

Sensor battery · % latest 100 %
90 95 100 105 110 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Signal strength · unit not reported latest -32
-37.5 -35.0 -32.5 -30.0 -27.5 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Record a status

Your verdict, recorded here and sent to Multiviz as a clear of the point: its priority drops to low and rises again only on what is detected after now. It counts once Multiviz has accepted the clear.


Axes

AxisPriorityLatest measurement
Stream 441e54f2 Low 2026-10-27 10:59 Analysis and trends →
Stream cdd367d6 Low 2026-10-27 10:59 Analysis and trends →
Stream ef24e7c0 Low 2026-10-27 10:59 Analysis and trends →

History

Priority

Each time the point's level changed, from Multiviz's priority history (bounded by the deployment). A fall to low says how the alert ended: a clear, or the evidence faded.

Data as ofPriorityWhat happenedBecause of
2026-10-27 10:59 Low — an analysis

Clears

Never cleared.