Attachments
Which sensor measures where. Multiviz knows the sensors that publish and the measuring points declared from them; the sites and machines above the measuring points are this app's, as your plant hierarchy is your system's. Resetting the app's state keeps all of it.
Sensors not mounted yet
These sensors publish, and their measurements are stored but never analysed until a measuring point is declared from them. Drag a sensor into a slot of a measuring point (or select it and click the slot), name the point, and declare it. The chip on each sensor is the axis it reports in its own frame (X, Y, Z); which of those is horizontal, vertical or axial depends on how it was bolted on, so only whoever mounted it can say. The choice is stored with each stream; record it in your own system too.
Not mounted
Every sensor that publishes is mounted, or on a card. A new one appears here as soon as it sends its first measurement.
New measuring points
Measuring points
Place each measuring point on its machine, with an optional component (Motor, Pump, …) and name; without a name it keeps the label it was declared with. A point on no machine is listed as unplaced on the overview, and still alerts.
| Measuring point | Placement |
|---|---|
| DE - Comp C 1ced4b54-4854-4a66-89d0-0ef8eb736a73 |
|
| NDE - Comp C cb4bd7d8-82e5-446e-8aaf-fab35cedb0c4 |
|
| DE - Comp C 0fb511a9-7ddf-488c-9811-2c92f8009158 |
|
| NDE - Comp C 10e4184d-c047-4b19-b102-14e3211c2e53 |
|
| DE - 602 04f8fae3-8ef8-4d04-b0be-e8103007c6f5 |
|
| DE - 602 56c77c40-a5aa-4c9d-8eba-906eec2e5e62 |
|
| DE - 601 357bc060-d624-418c-8d8e-fa8ac9e83284 |
|
| DE - 601 745a2bae-b55f-41a9-96e9-6b59c5bb4f92 |
|
| NDE - P100 f7396968-94fc-441c-8ef5-0f4575598406 |
|
| NDE - P100 b01be63c-d10e-441a-b539-01a21f2d9ea1 |
|
| DE - P100 c02ea56f-4e98-4432-b022-456ad1bde6be |
|
| DE - P100 fc27935e-1d43-488a-abb8-2931e5899926 |
|
| DE - 402 14ff5e19-d5d4-488d-b20c-e5ac3a83f1a9 |
|
| DE - 402 d1e525d0-c74b-4b88-9347-401a1f33164e |
|
| DE - 501 11763f09-af37-41bd-9dc3-64a572701de0 |
|
| DE - 501 12a66730-87bc-4baf-b1cd-78df78939dc5 |
|
| NDE - P200 6678f790-8845-417d-94ae-c628e073b157 |
|
| NDE - P200 e039692a-ef62-4d52-8c95-6a38a9ca1d93 |
|
| DE - P200 afd38e2a-4d57-419c-9eb7-76559336701e |
|
| DE - P200 f66e9ddf-0bcf-4ed1-a284-2551c2e64133 |
|
| DE - Comp A 6e79377a-3e8e-4098-82f3-416ebcd6f87a |
|
| NDE - Comp A 4ec2c365-f98d-407c-9888-06e61b22baa9 |
|
| DE - Comp A 384935a2-0217-495b-89a6-f9f985f0482d |
|
| NDE - Comp A 62a63eaa-4050-46b9-a734-1646c95fceed |
|
| NDE - Comp B b05d61a6-b503-40fb-a5ea-69bdf53608ed |
|
| NDE - Comp B 259d8d90-502c-44c3-a760-79f07699eb72 |
|
| DE - Comp B d7be6ad2-4077-48a4-9b4c-6c79adb32b85 |
|
| DE - Comp B ef5b6c0d-1296-4089-a9a8-5d4eda090887 |
|
| DE - 401 e347c9cb-e43c-41a5-b696-9a6765f6dbd1 |
|
| DE - 401 7c6752e1-55ca-4511-af00-fe3f23c54353 |
|
| DE - 502 1ffe3265-b869-4976-b851-b2d987e4fee3 |
|
| DE - 502 bc7730b6-25c8-4ef4-8647-f605275fd527 |
Sites and machines
Import or export the whole hierarchy as a file
Export the current hierarchy — the same format; export, edit and import again to change many points at once.
{
"sites": [
{
"name": "Mill 2",
"machines": [
{
"name": "Feed pump P-12",
"measuring_points": [
{"id": "PUMP-12-DE", "name": "Pump drive end", "component": "Pump"},
{"id": "PUMP-12-NDE", "component": "Pump"},
"MOTOR-12-DE"
]
}
]
}
]
}
id is the measuring point id the deployment lists. name and
component are optional. A bare string is just the id. Sites match by name, machines by
name within their site. Points may be listed before they are declared.
After a sensor replacement
A replacement sensor publishes as a new sensor, so it appears above among the sensors not mounted yet. Attach it to the stream the old one fed rather than declaring a new measuring point: the stream keeps its whole history across the swap, and its priority, clears and trends carry on.