Asset Twin example

DE - 402

Low Not assessed  Fan on HVAC / HV-FAN-402

Not in alert.

Likely faults

The latest analysis suggests no fault.

What changed

No active changes.

Trends

Measurement time 2026-09-26 18:58 to 2026-10-27 13:43 (UTC). ▏went into alert · ▏back to low, cleared or as the evidence faded — from Multiviz's priority history.

Vibration level

How strongly the machine vibrates at this point. A rise here is what usually lies behind an alert: compare it with the alert marks.

Velocity RMS · mm/s Stream 08675631 0.559 mm/s Stream c3e1d6ef 1.04 mm/s Stream da798ff1 1.04 mm/s
0.0 0.5 1.0 1.5 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 14.5 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Impacting

Short, sharp impacts, as from a damaged bearing, raise crest factor and kurtosis — often before the overall level moves.

Acceleration RMS · g Stream 08675631 0.089 g Stream c3e1d6ef 0.214 g Stream da798ff1 0.179 g
0.0 0.1 0.2 0.3 0.4 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 14.5 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Crest factor · peak ÷ RMS, no unit Stream 08675631 3.31 Stream c3e1d6ef 3.31 Stream da798ff1 3.34
2.5 3.0 3.5 4.0 4.5 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14.5 h.

Kurtosis · no unit; about 3 when nothing is impacting Stream 08675631 2.86 Stream c3e1d6ef 3.17 Stream da798ff1 3
2.0 2.5 3.0 3.5 4.0 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14.5 h.

Operating conditions

What the machine was doing. A change in speed or temperature explains many changes in vibration.

Temperature · °C latest 17 °C
14 16 18 20 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Speed

Nothing recorded for this measuring point yet.

Sensor health

About the sensor, not the machine: a flat battery or a weak signal shows up as gaps in the data.

Sensor battery · % latest 100 %
90 95 100 105 110 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Signal strength · unit not reported latest -46
-70 -60 -50 -40 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Record a status

Your verdict, recorded here and sent to Multiviz as a clear of the point: its priority drops to low and rises again only on what is detected after now. It counts once Multiviz has accepted the clear.


Axes

AxisPriorityLatest measurement
Stream 08675631 Low 2026-10-26 18:55 Analysis and trends →
Stream c3e1d6ef Low 2026-10-26 18:55 Analysis and trends →
Stream da798ff1 Low 2026-10-26 18:55 Analysis and trends →

History

Priority

Each time the point's level changed, from Multiviz's priority history (bounded by the deployment). A fall to low says how the alert ended: a clear, or the evidence faded.

Data as ofPriorityWhat happenedBecause of
2026-10-26 18:55 Low — an analysis

Clears

Never cleared.