Asset Twin example

DE - P100

Low Not assessed  Pump on Water treatment / WT-PMP-100

Not in alert.

Likely faults

FaultLikelihoodSeen on
Sensor issue 70% stream cd9e0aa9
VFD electrical noise 60% stream cd9e0aa9
Soft foot 30% stream cd9e0aa9
Structural looseness 30% stream cd9e0aa9
Loose connections 10% stream cd9e0aa9

Each axis is analysed on its own; a fault seen on several shows the highest likelihood any of them reports, never a sum.

What changed

Jump in Acceleration RMS (scalar)
Typical level of Acceleration RMS (scalar) has increased from <<0.54:g>> to <<0.74:g>>.
stream 16acde75 2026-10-15 06:46
Low Frequency
Change in velocity for low frequency band <<56-62:Hz>> for mode 5 has been detected.
stream cd9e0aa9 2026-10-13 18:04
Low Frequency
Change in velocity for low frequency band <<2-8:Hz>> for mode 5 has been detected.
stream 16acde75 2026-10-09 19:57
Emerging Mode
New mode 6 has been detected.
stream 16acde75 2026-10-09 07:20
Emerging Mode
New mode 5 has been detected.
stream cd9e0aa9 2026-10-09 07:20
Jump in Acceleration RMS (scalar)
Typical level of Acceleration RMS (scalar) has increased from <<0.36:g>> to <<0.55:g>>.
stream 16acde75 2026-10-03 00:25
Low Frequency
Change in velocity for low frequency band <<56-62:Hz>> for mode 3 has been detected.
stream cd9e0aa9 2026-09-26 20:51

Trends

Measurement time 2026-09-26 14:12 to 2026-10-27 13:42 (UTC). ▏went into alert · ▏back to low, cleared or as the evidence faded — from Multiviz's priority history.

Vibration level

How strongly the machine vibrates at this point. A rise here is what usually lies behind an alert: compare it with the alert marks.

Velocity RMS · mm/s Stream 16acde75 1.37 mm/s Stream 9ca9e91d 0.889 mm/s Stream cd9e0aa9 2.21 mm/s
0 2 4 6 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 13 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Impacting

Short, sharp impacts, as from a damaged bearing, raise crest factor and kurtosis — often before the overall level moves.

Acceleration RMS · g Stream 16acde75 0.352 g Stream 9ca9e91d 0.194 g Stream cd9e0aa9 0.367 g
0.00 0.25 0.50 0.75 1.00 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 13 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Crest factor · peak ÷ RMS, no unit Stream 16acde75 3.64 Stream 9ca9e91d 3.18 Stream cd9e0aa9 2.95
0 2 4 6 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Kurtosis · no unit; about 3 when nothing is impacting Stream 16acde75 3.26 Stream 9ca9e91d 2.83 Stream cd9e0aa9 2.17
0 2 4 6 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Operating conditions

What the machine was doing. A change in speed or temperature explains many changes in vibration.

Temperature · °C latest 35 °C
0 10 20 30 40 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Speed

Nothing recorded for this measuring point yet.

Sensor health

About the sensor, not the machine: a flat battery or a weak signal shows up as gaps in the data.

Sensor battery · % latest 100 %
90 95 100 105 110 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Signal strength · unit not reported latest -33
-40.0 -37.5 -35.0 -32.5 -30.0 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Record a status

Your verdict, recorded here and sent to Multiviz as a clear of the point: its priority drops to low and rises again only on what is detected after now. It counts once Multiviz has accepted the clear.


Axes

AxisPriorityLatest measurement
Stream 16acde75 Low 2026-10-26 14:08 Analysis and trends →
Stream 9ca9e91d Low 2026-10-26 14:08 Analysis and trends →
Stream cd9e0aa9 Low 2026-10-26 14:08 Analysis and trends →

History

Priority

Each time the point's level changed, from Multiviz's priority history (bounded by the deployment). A fall to low says how the alert ended: a clear, or the evidence faded.

Data as ofPriorityWhat happenedBecause of
2026-10-26 14:08 Low — an analysis

Clears

Never cleared.