Asset Twin example

DE - P100 · Unknown axis

Low  latest measurement 2026-10-26 14:08

Trends

Measurement time 2026-09-26 14:12 to 2026-10-27 13:42 (UTC). ▏went into alert · ▏back to low, cleared or as the evidence faded — from Multiviz's priority history.

Vibration level

How strongly the machine vibrates at this point. A rise here is what usually lies behind an alert: compare it with the alert marks.

Velocity RMS · mm/s latest 2.21 mm/s
0 1 2 3 4 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 13 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Impacting

Short, sharp impacts, as from a damaged bearing, raise crest factor and kurtosis — often before the overall level moves.

Acceleration RMS · g latest 0.367 g
0.0 0.2 0.4 0.6 0.8 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 13 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Crest factor · peak ÷ RMS, no unit latest 2.95
0 2 4 6 Oct 01 Oct 08 Oct 15 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Kurtosis · no unit; about 3 when nothing is impacting latest 2.17
0 2 4 6 Oct 01 Oct 08 Oct 15 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Operating conditions

What the machine was doing. A change in speed or temperature explains many changes in vibration.

Temperature · °C latest 35 °C
0 10 20 30 40 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min.

Speed

Nothing recorded for this axis yet.

Sensor health

About the sensor, not the machine: a flat battery or a weak signal shows up as gaps in the data.

Sensor battery · % latest 100 %
90 95 100 105 110 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Signal strength · unit not reported latest -33
-40.0 -37.5 -35.0 -32.5 -30.0 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Other measures from each waveform

Everything else MultiViz computes from each measurement of this axis.

Envelope peak score · g² latest 0.183 g²
0.0 0.2 0.4 0.6 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Envelope RMS · g² latest 0.151 g²
0.0 0.1 0.2 0.3 0.4 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Peak acceleration · g latest 1.07 g
0.0 0.5 1.0 1.5 2.0 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Peak-to-peak acceleration · g latest 2 g
0 1 2 3 4 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Velocity RMS, from 10 Hz up · mm/s latest 1.43 mm/s
0 1 2 3 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Velocity RMS, 2-1000 Hz · mm/s latest 1.45 mm/s
0 1 2 3 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Velocity RMS, from 2 Hz up · mm/s latest 1.46 mm/s
0 1 2 3 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Analysis

Priority over time

FromPriorityBecause of
2026-10-27 15:27Lowan analysis