Asset Twin example

NDE - P100

Low Not assessed  Pump on Water treatment / WT-PMP-100

Not in alert.

Likely faults

FaultLikelihoodSeen on
Sensor issue 70% stream 934e115b
Rotating looseness 70% stream ba8780d6
Structural looseness 30% stream 934e115b
Process related harmonics 30% stream ba8780d6

Each axis is analysed on its own; a fault seen on several shows the highest likelihood any of them reports, never a sum.

What changed

Emerging Mode
New mode 6 has been detected.
stream 5de25f79 2026-10-06 20:46
Emerging Mode
New mode 5 has been detected.
stream ba8780d6 2026-10-06 20:46

Trends

Measurement time 2026-09-26 17:52 to 2026-10-27 13:42 (UTC). ▏went into alert · ▏back to low, cleared or as the evidence faded — from Multiviz's priority history.

Vibration level

How strongly the machine vibrates at this point. A rise here is what usually lies behind an alert: compare it with the alert marks.

Velocity RMS · mm/s Stream 5de25f79 1.55 mm/s Stream 934e115b 1.04 mm/s Stream ba8780d6 1.32 mm/s
0 2 4 6 8 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 13 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Impacting

Short, sharp impacts, as from a damaged bearing, raise crest factor and kurtosis — often before the overall level moves.

Acceleration RMS · g Stream 5de25f79 0.322 g Stream 934e115b 0.25 g Stream ba8780d6 0.38 g
0.0 0.5 1.0 1.5 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 13 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Crest factor · peak ÷ RMS, no unit Stream 5de25f79 3.51 Stream 934e115b 3.57 Stream ba8780d6 2.82
0 2 4 6 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Kurtosis · no unit; about 3 when nothing is impacting Stream 5de25f79 3.02 Stream 934e115b 2.95 Stream ba8780d6 2.33
0 1 2 3 4 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Operating conditions

What the machine was doing. A change in speed or temperature explains many changes in vibration.

Temperature · °C latest 36 °C
0 10 20 30 40 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Speed

Nothing recorded for this measuring point yet.

Sensor health

About the sensor, not the machine: a flat battery or a weak signal shows up as gaps in the data.

Sensor battery · % latest 100 %
90 95 100 105 110 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Signal strength · unit not reported latest -41
-45 -40 -35 -30 -25 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Record a status

Your verdict, recorded here and sent to Multiviz as a clear of the point: its priority drops to low and rises again only on what is detected after now. It counts once Multiviz has accepted the clear.


Axes

AxisPriorityLatest measurement
Stream 5de25f79 Low 2026-10-26 17:50 Analysis and trends →
Stream 934e115b Low 2026-10-26 17:50 Analysis and trends →
Stream ba8780d6 Low 2026-10-26 17:50 Analysis and trends →

History

Priority

Each time the point's level changed, from Multiviz's priority history (bounded by the deployment). A fall to low says how the alert ended: a clear, or the evidence faded.

Data as ofPriorityWhat happenedBecause of
2026-10-26 17:50 Low — an analysis

Clears

Never cleared.