Asset Twin example

DE - P200

Low Not assessed  Motor on Water treatment / WT-PMP-200

Not in alert.

Likely faults

FaultLikelihoodSeen on
VFD electrical noise 60% stream 518d32a3
Soft foot 30% stream 518d32a3
Loose connections 10% stream 518d32a3

Each axis is analysed on its own; a fault seen on several shows the highest likelihood any of them reports, never a sum.

What changed

No active changes.

Trends

Measurement time 2026-09-26 20:43 to 2026-10-27 13:41 (UTC). ▏went into alert · ▏back to low, cleared or as the evidence faded — from Multiviz's priority history.

Vibration level

How strongly the machine vibrates at this point. A rise here is what usually lies behind an alert: compare it with the alert marks.

Velocity RMS · mm/s Stream 3e1e584b 3.84 mm/s Stream 518d32a3 1.88 mm/s Stream 97b25da9 2.36 mm/s
0 2 4 6 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 13 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Impacting

Short, sharp impacts, as from a damaged bearing, raise crest factor and kurtosis — often before the overall level moves.

Acceleration RMS · g Stream 3e1e584b 0.623 g Stream 518d32a3 0.424 g Stream 97b25da9 0.36 g
0.00 0.25 0.50 0.75 1.00 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 13 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Crest factor · peak ÷ RMS, no unit Stream 3e1e584b 3.49 Stream 518d32a3 3.89 Stream 97b25da9 3.45
0 2 4 6 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Kurtosis · no unit; about 3 when nothing is impacting Stream 3e1e584b 3.11 Stream 518d32a3 3.5 Stream 97b25da9 3.05
0 1 2 3 4 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Operating conditions

What the machine was doing. A change in speed or temperature explains many changes in vibration.

Temperature · °C latest 28 °C
0 10 20 30 40 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Speed

Nothing recorded for this measuring point yet.

Sensor health

About the sensor, not the machine: a flat battery or a weak signal shows up as gaps in the data.

Sensor battery · % latest 100 %
90 95 100 105 110 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Signal strength · unit not reported latest -30
-70 -60 -50 -40 -30 -20 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Record a status

Your verdict, recorded here and sent to Multiviz as a clear of the point: its priority drops to low and rises again only on what is detected after now. It counts once Multiviz has accepted the clear.


Axes

AxisPriorityLatest measurement
Stream 3e1e584b Low 2026-10-26 20:42 Analysis and trends →
Stream 518d32a3 Low 2026-10-26 20:42 Analysis and trends →
Stream 97b25da9 Low 2026-10-26 20:42 Analysis and trends →

History

Priority

Each time the point's level changed, from Multiviz's priority history (bounded by the deployment). A fall to low says how the alert ended: a clear, or the evidence faded.

Data as ofPriorityWhat happenedBecause of
2026-10-26 20:42 Low — an analysis

Clears

Never cleared.