Asset Twin example

NDE - Comp C

Low Not assessed  Motor on Cooling / CL-COMP-C

Not in alert.

Likely faults

The latest analysis suggests no fault.

What changed

Jump in Envelope Peak Score
Typical level of Envelope Peak Score has increased from <<0.22:g^2>> to <<0.6:g^2>>.
stream 308c5096 2026-10-12 21:06
Jump in Envelope Peak Score
Typical level of Envelope Peak Score has increased from <<0.63:g^2>> to <<2.17:g^2>>.
stream 5e985d19 2026-10-12 21:06
Jump in Acceleration RMS (scalar)
Typical level of Acceleration RMS (scalar) has increased from <<0.41:g>> to <<0.67:g>>.
stream 5e985d19 2026-10-08 14:54
Jump in Velocity RMS (scalar)
Typical level of Velocity RMS (scalar) has increased from <<1.5:mm/s>> to <<2.16:mm/s>>.
stream 308c5096 2026-10-03 06:43
Jump in Velocity RMS (scalar)
Typical level of Velocity RMS (scalar) has increased from <<0.33:mm/s>> to <<1.5:mm/s>>.
stream 308c5096 2026-10-02 18:53

Trends

Measurement time 2026-09-27 11:48 to 2026-10-27 13:40 (UTC). ▏went into alert · ▏back to low, cleared or as the evidence faded — from Multiviz's priority history.

Vibration level

How strongly the machine vibrates at this point. A rise here is what usually lies behind an alert: compare it with the alert marks.

Velocity RMS · mm/s Stream 308c5096 0 mm/s Stream 3ff5f5f5 0 mm/s Stream 5e985d19 0 mm/s
0.0 2.5 5.0 7.5 10.0 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 40 min); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Impacting

Short, sharp impacts, as from a damaged bearing, raise crest factor and kurtosis — often before the overall level moves.

Acceleration RMS · g Stream 308c5096 0 g Stream 3ff5f5f5 0 g Stream 5e985d19 0 g
0.00 0.25 0.50 0.75 1.00 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 40 min); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Crest factor · peak ÷ RMS, no unit Stream 308c5096 0 Stream 3ff5f5f5 0 Stream 5e985d19 0
0 2 4 6 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 40 min.

Kurtosis · no unit; about 3 when nothing is impacting Stream 308c5096 0 Stream 3ff5f5f5 0 Stream 5e985d19 0
0 1 2 3 4 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 40 min.

Operating conditions

What the machine was doing. A change in speed or temperature explains many changes in vibration.

Temperature · °C latest 0 °C
0 10 20 30 40 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Speed

Nothing recorded for this measuring point yet.

Sensor health

About the sensor, not the machine: a flat battery or a weak signal shows up as gaps in the data.

Sensor battery · % latest 100 %
90 95 100 105 110 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Signal strength · unit not reported latest -34
-45 -40 -35 -30 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Record a status

Your verdict, recorded here and sent to Multiviz as a clear of the point: its priority drops to low and rises again only on what is detected after now. It counts once Multiviz has accepted the clear.


Axes

AxisPriorityLatest measurement
Stream 308c5096 Low 2026-10-27 11:45 Analysis and trends →
Stream 3ff5f5f5 Low 2026-10-27 11:45 Analysis and trends →
Stream 5e985d19 Low 2026-10-27 11:45 Analysis and trends →

History

Priority

Each time the point's level changed, from Multiviz's priority history (bounded by the deployment). A fall to low says how the alert ended: a clear, or the evidence faded.

Data as ofPriorityWhat happenedBecause of
2026-10-27 11:45 Low — an analysis

Clears

Never cleared.