Asset Twin example

DE - Comp A · Unknown axis

Low  latest measurement 2026-10-26 20:27

Trends

Measurement time 2026-09-26 20:32 to 2026-10-27 13:39 (UTC). ▏went into alert · ▏back to low, cleared or as the evidence faded — from Multiviz's priority history.

Vibration level

How strongly the machine vibrates at this point. A rise here is what usually lies behind an alert: compare it with the alert marks.

Velocity RMS · mm/s latest 0.229 mm/s
0.0 0.2 0.4 0.6 0.8 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 13 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Impacting

Short, sharp impacts, as from a damaged bearing, raise crest factor and kurtosis — often before the overall level moves.

Acceleration RMS · g latest 0.02 g
0.00 0.02 0.04 0.06 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 13 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Crest factor · peak ÷ RMS, no unit latest 3.14
2.5 3.0 3.5 4.0 4.5 Oct 01 Oct 08 Oct 15 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Kurtosis · no unit; about 3 when nothing is impacting latest 2.46
2.0 2.5 3.0 3.5 4.0 Oct 01 Oct 08 Oct 15 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Operating conditions

What the machine was doing. A change in speed or temperature explains many changes in vibration.

Temperature · °C latest 24 °C
20 22 24 26 28 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min.

Speed

Nothing recorded for this axis yet.

Sensor health

About the sensor, not the machine: a flat battery or a weak signal shows up as gaps in the data.

Sensor battery · % latest 100 %
90 95 100 105 110 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Signal strength · unit not reported latest -32
-36 -34 -32 -30 -28 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Other measures from each waveform

Everything else MultiViz computes from each measurement of this axis.

Envelope peak score · g² latest 0.00134 g²
0.000 0.002 0.004 0.006 0.008 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Envelope RMS · g² latest 0.00127 g²
0.000 0.001 0.002 0.003 0.004 0.005 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Peak acceleration · g latest 0.095 g
0.050 0.075 0.100 0.125 0.150 0.175 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Peak-to-peak acceleration · g latest 0.18 g
0.10 0.15 0.20 0.25 0.30 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Velocity RMS, from 10 Hz up · mm/s latest 0.103 mm/s
0.0 0.1 0.2 0.3 0.4 0.5 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Velocity RMS, 2-1000 Hz · mm/s latest 0.125 mm/s
0.0 0.1 0.2 0.3 0.4 0.5 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Velocity RMS, from 2 Hz up · mm/s latest 0.126 mm/s
0.0 0.1 0.2 0.3 0.4 0.5 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 13 h.

Analysis

Priority over time

FromPriorityBecause of
2026-10-27 14:37Lowan analysis