Asset Twin example

NDE - P200 · Unknown axis

Not analysed

Trends

Measurement time 2026-09-26 23:46 to 2026-10-27 13:39 (UTC). ▏went into alert · ▏back to low, cleared or as the evidence faded — from Multiviz's priority history.

Vibration level

How strongly the machine vibrates at this point. A rise here is what usually lies behind an alert: compare it with the alert marks.

Velocity RMS · mm/s latest 2.24 mm/s
0 2 4 6 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 14 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Impacting

Short, sharp impacts, as from a damaged bearing, raise crest factor and kurtosis — often before the overall level moves.

Acceleration RMS · g latest 0.436 g
0.0 0.2 0.4 0.6 0.8 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min. MultiViz also computes it from each waveform (about every 14 h); the sensor's value is shown because it comes more often. The two may differ: each uses its own frequency range.

Crest factor · peak ÷ RMS, no unit latest 3.59
0 2 4 6 Oct 01 Oct 08 Oct 15 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14 h.

Kurtosis · no unit; about 3 when nothing is impacting latest 3.05
0 1 2 3 4 Oct 01 Oct 08 Oct 15 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14 h.

Operating conditions

What the machine was doing. A change in speed or temperature explains many changes in vibration.

Temperature · °C latest 30 °C
0 20 40 60 Oct 01 Oct 08 Oct 15 Oct 22

Reported by the sensor itself, about every 5 min.

Speed

Nothing recorded for this axis yet.

Sensor health

About the sensor, not the machine: a flat battery or a weak signal shows up as gaps in the data.

Sensor battery · % latest 100 %
90 95 100 105 110 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Signal strength · unit not reported latest -37
-70 -60 -50 -40 -30 Oct 08 Oct 22

Reported by the sensor itself, about every 5 min.

Other measures from each waveform

Everything else MultiViz computes from each measurement of this axis.

Envelope peak score · g² latest 0.782 g²
0 5 10 15 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14 h.

Envelope RMS · g² latest 1.54 g²
0 5 10 15 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14 h.

Peak acceleration · g latest 3.21 g
0.0 2.5 5.0 7.5 10.0 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14 h.

Peak-to-peak acceleration · g latest 6.14 g
0 5 10 15 20 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14 h.

Velocity RMS, from 10 Hz up · mm/s latest 2.46 mm/s
0 1 2 3 4 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14 h.

Velocity RMS, 2-1000 Hz · mm/s latest 2.38 mm/s
0 1 2 3 4 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14 h.

Velocity RMS, from 2 Hz up · mm/s latest 2.49 mm/s
0 1 2 3 4 Oct 08 Oct 22

Computed by MultiViz from each vibration measurement (waveform), about every 14 h.

Analysis

Priority over time

Not analysed yet.